- Suitable for humid environments
- Airtight with a hollow sealing gasket, tested to window class 3
- Thermal and acoustic insulation in accordance with rt 2020
- Insulating material in accordance with “öko-tex 100” standard, class 1
TECHNICAL DEFINITION
BUILDING ELEMENT : - Metal hatch, frame and panel - Sealing gasket - Spring hinge - Spring catch (mini-latch) - Insulating material
MATERIAL : - Steel sheet, galvanised, painted white (RAL 9016) - EPDM, white - Spring steel sheet - Steel / plastic / spring steel - Polyester fleece (23.5kg/m³)
BUILDING ELEMENT : - Metal hatch, frame and panel - Sealing gasket - Spring hinge - Spring catch (mini-latch) - Insulating material
MATERIAL : - Steel sheet, galvanised, painted white (RAL 9016) - EPDM, white - Spring steel sheet - Steel / plastic / spring steel - Polyester fleece (23.5kg/m³)
COMPOSITION
Access hatch
Extension frame
Insulating cushions (vacuum-packed)
Installation instructions
Access hatch
Extension frame
Insulating cushions (vacuum-packed)
Installation instructions
DIMENSION_POSSIBLE
550 x 550
550 x 550
USE :
The access hatch components must be cleaned with mild standard detergents or dry-cleaned. The hatch must always remain properly closed.
If not, check that the catches are working correctly. Otherwise, the inspection hatch is maintenance-free.
The access hatch components must be cleaned with mild standard detergents or dry-cleaned. The hatch must always remain properly closed.
If not, check that the catches are working correctly. Otherwise, the inspection hatch is maintenance-free.
USE
Simple mounting of the recessed frame into the ceiling opening (approximately 5 mm larger than the recessed dimensions).
The screws are fixed using wall anchors inserted laterally into the ceiling opening. Always follow the enclosed installation instructions!
Simple mounting of the recessed frame into the ceiling opening (approximately 5 mm larger than the recessed dimensions).
The screws are fixed using wall anchors inserted laterally into the ceiling opening. Always follow the enclosed installation instructions!
AVAILABLE DOCUMENTATION
Airtightness: in accordance with EN 12207 for windows and doors, Class 3 (at 100 Pa)
Airborne sound insulation in accordance with DIN EN ISO 10140: Dw = 54 dB, Rw = 38.8 dB
Insulating material: polyester fleece (t = 340 mm): R = 10m².K/W
Airtightness: in accordance with EN 12207 for windows and doors, Class 3 (at 100 Pa)
Airborne sound insulation in accordance with DIN EN ISO 10140: Dw = 54 dB, Rw = 38.8 dB
Insulating material: polyester fleece (t = 340 mm): R = 10m².K/W